ダウンロード数: 291

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
s00421-019-04098-6.pdf615.7 kBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorMasaki, Mitsuhiroen
dc.contributor.authorJi, Xiangen
dc.contributor.authorYamauchi, Taishien
dc.contributor.authorTateuchi, Hiroshigeen
dc.contributor.authorIchihashi, Noriakien
dc.contributor.alternative建内, 宏重ja
dc.contributor.alternative市橋, 則明ja
dc.date.accessioned2021-09-14T09:22:04Z-
dc.date.available2021-09-14T09:22:04Z-
dc.date.issued2019-05-
dc.identifier.urihttp://hdl.handle.net/2433/265259-
dc.description.abstractPURPOSE: The present study aimed to clarify the effects of the trunk position on muscle stiffness that reflects elongation of the lumbar erector spinae and lumbar multifidus muscles using ultrasonic shear wave elastography (SWE). METHODS: The study included ten healthy men. The shear elastic modulus of the left lumbar erector spinae and lumbar multifidus muscles were evaluated using ultrasonic SWE. Measurement postures for the left lumbar erector spinae muscle were (1) prone position (Rest), (2) sitting position with the trunk flexed (Flexion), (3) the Flexion position adding right trunk lateral flexion (Flexion-Lateral Flexion), and (4) the Flexion position adding right trunk rotation (Flexion-Rotation 1). The left lumbar multifidus muscle were measured in positions (1)-(3), and (5) the Flexion position adding left trunk rotation (Flexion-Rotation 2). RESULTS: The shear elastic modulus of the lumbar erector spinae muscle in the Flexion-Lateral Flexion position was significantly higher than that in the Rest, Flexion, or Flexion-Rotation 1 positions. Shear elastic modulus of the lumbar multifidus muscle was similar in the Flexion, Flexion-Lateral Flexion, and Flexion-Rotation 2 positions, but significantly lower in the Rest position. CONCLUSIONS: The results of the present study suggest that the lumbar erector spinae muscle is stretched effectively in the position adding trunk contralateral lateral flexion to flexion. The results also indicate that the lumbar multifidus muscle, which does not appear to be affected by adding trunk contralateral lateral flexion or ipsilateral rotation to flexion, is stretched effectively in the trunk flexion position.en
dc.language.isoeng-
dc.publisherSpringer Natureen
dc.rightsThis is a post-peer-review, pre-copyedit version of an article published in European journal of applied physiology. The final authenticated version is available online at: http://dx.doi.org/10.1007/s00421-019-04098-6.en
dc.rightsThe full-text file will be made open to the public on 12 February 2020 in accordance with publisher's 'Terms and Conditions for Self-Archiving'.en
dc.rightsThis is not the published version. Please cite only the published version. この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。en
dc.subjectParaspinal musclesen
dc.subjectMuscle elongationen
dc.subjectMuscle stiffnessen
dc.subjectUltrasonographyen
dc.titleEffects of the trunk position on muscle stiffness that reflects elongation of the lumbar erector spinae and multifidus muscles: an ultrasonic shear wave elastography study.en
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleEuropean journal of applied physiologyen
dc.identifier.volume119-
dc.identifier.issue5-
dc.identifier.spage1085-
dc.identifier.epage1091-
dc.relation.doi10.1007/s00421-019-04098-6-
dc.textversionauthor-
dc.identifier.pmid30747266-
dcterms.accessRightsopen access-
datacite.date.available2020-02-12-
datacite.awardNumber15H03043-
datacite.awardNumber.urihttps://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-15H03043/-
dc.identifier.pissn1439-6319-
dc.identifier.eissn1439-6327-
jpcoar.funderName日本学術振興会ja
jpcoar.awardTitle新たな筋伸張指標を用いた最適なストレッチング法の開発ja
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。