このアイテムのアクセス数: 151

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
mds.28417.pdf1.16 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorOshima, Sonokoen
dc.contributor.authorFushimi, Yasutakaen
dc.contributor.authorOkada, Tomohisaen
dc.contributor.authorNakajima, Satoshien
dc.contributor.authorYokota, Yusukeen
dc.contributor.authorShima, Atsushien
dc.contributor.authorGrinstead, Johnen
dc.contributor.authorAhn, Sinyeoben
dc.contributor.authorSawamoto, Nobukatsuen
dc.contributor.authorTakahashi, Ryosukeen
dc.contributor.authorNakamoto, Yujien
dc.contributor.alternative大嶋, 園子ja
dc.contributor.alternative伏見, 育崇ja
dc.contributor.alternative岡田, 知久ja
dc.contributor.alternative中島, 諭ja
dc.contributor.alternative横田, 悠介ja
dc.contributor.alternative島, 淳ja
dc.contributor.alternative澤本, 伸克ja
dc.contributor.alternative髙橋, 良輔ja
dc.contributor.alternative中本, 裕士ja
dc.date.accessioned2022-09-30T05:57:14Z-
dc.date.available2022-09-30T05:57:14Z-
dc.date.issued2021-04-
dc.identifier.urihttp://hdl.handle.net/2433/276409-
dc.description.abstractBACKGROUND: Neuromelanin-sensitive magnetic resonance imaging techniques have been developed but currently require relatively long scan times. The aim of this study was to assess the ability of black-blood delay alternating with nutation for tailored excitation-prepared T1-weighted variable flip angle turbo spin echo (DANTE T1-SPACE), which provides relatively high resolution with a short scan time, to visualize neuromelanin in the substantia nigra pars compacta (SNpc). METHODS: Participants comprised 49 healthy controls and 25 patients with Parkinson's disease (PD). Contrast ratios of SNpc and hyperintense SNpc areas, which show pixels brighter than thresholds, were assessed between DANTE T1-SPACE and T1-SPACE in healthy controls. To evaluate the diagnostic ability of DANTE T1-SPACE, the contrast ratios and hyperintense areas were compared between healthy and PD groups, and receiver operating characteristic analyses were performed. We also compared areas under the curve (AUCs) between DANTE T1-SPACE and the previously reported gradient echo neuromelanin (GRE-NM) imaging. Each analysis was performed using original images in native space and images transformed into Montreal Neurological Institute space. Values of P < 0.05 were considered significant. RESULTS: DANTE T1-SPACE showed significantly higher contrast ratios and larger hyperintense areas than T1-SPACE. On DANTE T1-SPACE, healthy controls showed significantly higher contrast ratios and larger hyperintense areas than patients with PD. Hyperintense areas in native space analysis achieved the best AUC (0.94). DANTE T1-SPACE showed AUCs as high as those of GRE-NM. CONCLUSIONS: DANTE T1-SPACE successfully visualized neuromelanin of the SNpc and showed potential for evaluating PD. © 2020 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.en
dc.language.isoeng-
dc.publisherWileyen
dc.publisherInternational Parkinson and Movement Disorder Societyen
dc.rights© 2020 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Societyen
dc.rightsThis is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.en
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/-
dc.subjectParkinson's diseaseen
dc.subjectmagnetic resonance imagingen
dc.subjectneuromelaninen
dc.subjectsubstantia nigraen
dc.titleNeuromelanin‐Sensitive Magnetic Resonance Imaging Using DANTE Pulseen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleMovement Disordersen
dc.identifier.volume36-
dc.identifier.issue4-
dc.identifier.spage874-
dc.identifier.epage882-
dc.relation.doi10.1002/mds.28417-
dc.textversionpublisher-
dc.identifier.pmid33314293-
dcterms.accessRightsopen access-
datacite.awardNumber18K07711-
datacite.awardNumber19K17266-
datacite.awardNumber.urihttps://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-18K07711/-
datacite.awardNumber.urihttps://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-19K17266/-
dc.identifier.pissn0885-3185-
dc.identifier.eissn1531-8257-
jpcoar.funderName日本学術振興会ja
jpcoar.funderName日本学術振興会ja
jpcoar.awardTitle圧縮センシングの脳・頸部MRIへの応用ja
jpcoar.awardTitle急性期脳梗塞および脳血管異常のリアルタイム検出ja
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス Creative Commons