このアイテムのアクセス数: 151
このアイテムのファイル:
ファイル | 記述 | サイズ | フォーマット | |
---|---|---|---|---|
mds.28417.pdf | 1.16 MB | Adobe PDF | 見る/開く |
完全メタデータレコード
DCフィールド | 値 | 言語 |
---|---|---|
dc.contributor.author | Oshima, Sonoko | en |
dc.contributor.author | Fushimi, Yasutaka | en |
dc.contributor.author | Okada, Tomohisa | en |
dc.contributor.author | Nakajima, Satoshi | en |
dc.contributor.author | Yokota, Yusuke | en |
dc.contributor.author | Shima, Atsushi | en |
dc.contributor.author | Grinstead, John | en |
dc.contributor.author | Ahn, Sinyeob | en |
dc.contributor.author | Sawamoto, Nobukatsu | en |
dc.contributor.author | Takahashi, Ryosuke | en |
dc.contributor.author | Nakamoto, Yuji | en |
dc.contributor.alternative | 大嶋, 園子 | ja |
dc.contributor.alternative | 伏見, 育崇 | ja |
dc.contributor.alternative | 岡田, 知久 | ja |
dc.contributor.alternative | 中島, 諭 | ja |
dc.contributor.alternative | 横田, 悠介 | ja |
dc.contributor.alternative | 島, 淳 | ja |
dc.contributor.alternative | 澤本, 伸克 | ja |
dc.contributor.alternative | 髙橋, 良輔 | ja |
dc.contributor.alternative | 中本, 裕士 | ja |
dc.date.accessioned | 2022-09-30T05:57:14Z | - |
dc.date.available | 2022-09-30T05:57:14Z | - |
dc.date.issued | 2021-04 | - |
dc.identifier.uri | http://hdl.handle.net/2433/276409 | - |
dc.description.abstract | BACKGROUND: Neuromelanin-sensitive magnetic resonance imaging techniques have been developed but currently require relatively long scan times. The aim of this study was to assess the ability of black-blood delay alternating with nutation for tailored excitation-prepared T1-weighted variable flip angle turbo spin echo (DANTE T1-SPACE), which provides relatively high resolution with a short scan time, to visualize neuromelanin in the substantia nigra pars compacta (SNpc). METHODS: Participants comprised 49 healthy controls and 25 patients with Parkinson's disease (PD). Contrast ratios of SNpc and hyperintense SNpc areas, which show pixels brighter than thresholds, were assessed between DANTE T1-SPACE and T1-SPACE in healthy controls. To evaluate the diagnostic ability of DANTE T1-SPACE, the contrast ratios and hyperintense areas were compared between healthy and PD groups, and receiver operating characteristic analyses were performed. We also compared areas under the curve (AUCs) between DANTE T1-SPACE and the previously reported gradient echo neuromelanin (GRE-NM) imaging. Each analysis was performed using original images in native space and images transformed into Montreal Neurological Institute space. Values of P < 0.05 were considered significant. RESULTS: DANTE T1-SPACE showed significantly higher contrast ratios and larger hyperintense areas than T1-SPACE. On DANTE T1-SPACE, healthy controls showed significantly higher contrast ratios and larger hyperintense areas than patients with PD. Hyperintense areas in native space analysis achieved the best AUC (0.94). DANTE T1-SPACE showed AUCs as high as those of GRE-NM. CONCLUSIONS: DANTE T1-SPACE successfully visualized neuromelanin of the SNpc and showed potential for evaluating PD. © 2020 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society. | en |
dc.language.iso | eng | - |
dc.publisher | Wiley | en |
dc.publisher | International Parkinson and Movement Disorder Society | en |
dc.rights | © 2020 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society | en |
dc.rights | This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. | en |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | - |
dc.subject | Parkinson's disease | en |
dc.subject | magnetic resonance imaging | en |
dc.subject | neuromelanin | en |
dc.subject | substantia nigra | en |
dc.title | Neuromelanin‐Sensitive Magnetic Resonance Imaging Using DANTE Pulse | en |
dc.type | journal article | - |
dc.type.niitype | Journal Article | - |
dc.identifier.jtitle | Movement Disorders | en |
dc.identifier.volume | 36 | - |
dc.identifier.issue | 4 | - |
dc.identifier.spage | 874 | - |
dc.identifier.epage | 882 | - |
dc.relation.doi | 10.1002/mds.28417 | - |
dc.textversion | publisher | - |
dc.identifier.pmid | 33314293 | - |
dcterms.accessRights | open access | - |
datacite.awardNumber | 18K07711 | - |
datacite.awardNumber | 19K17266 | - |
datacite.awardNumber.uri | https://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-18K07711/ | - |
datacite.awardNumber.uri | https://kaken.nii.ac.jp/ja/grant/KAKENHI-PROJECT-19K17266/ | - |
dc.identifier.pissn | 0885-3185 | - |
dc.identifier.eissn | 1531-8257 | - |
jpcoar.funderName | 日本学術振興会 | ja |
jpcoar.funderName | 日本学術振興会 | ja |
jpcoar.awardTitle | 圧縮センシングの脳・頸部MRIへの応用 | ja |
jpcoar.awardTitle | 急性期脳梗塞および脳血管異常のリアルタイム検出 | ja |
出現コレクション: | 学術雑誌掲載論文等 |

このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス