このアイテムのアクセス数: 45

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
ace.22011.pdf1.37 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorKuwauchi, Akien
dc.contributor.authorYoshida, Satomien
dc.contributor.authorTanaka, Shiroen
dc.contributor.authorTanaka, Sachikoen
dc.contributor.authorTakeda, Chikashien
dc.contributor.authorYonekura, Hiroshien
dc.contributor.authorNahara, Isaoen
dc.contributor.authorKawakami, Kojien
dc.contributor.alternative桑内, 亜紀ja
dc.contributor.alternative吉田, 都美ja
dc.contributor.alternative田中, 司朗ja
dc.contributor.alternative田中, 佐智子ja
dc.contributor.alternative武田, 親宗ja
dc.contributor.alternative米倉, 寛ja
dc.contributor.alternative名原, 功ja
dc.contributor.alternative川上, 浩司ja
dc.date.accessioned2024-02-01T08:37:57Z-
dc.date.available2024-02-01T08:37:57Z-
dc.date.issued2022-
dc.identifier.urihttp://hdl.handle.net/2433/286851-
dc.description.abstract[BACKGROUND] The controversy concerning the benefits of pulmonary artery catheter (PAC)-based hemodynamic monitoring in cardiac surgeries has not been adequately addressed. This study aims to compare the all-cause mortality between the PAC with venous oxygen saturation monitoring and the Vigileo/FloTrac (FloTrac) system with central venous oxygen saturation monitoring in cardiac surgeries. [METHODS] This nationwide retrospective study includes adult patients who underwent elective cardiac surgeries between April 2010 and October 2014, based on the Japanese health insurance claims database. The main outcome was 30-day all-cause mortality. Propensity scores (PS) were used to adjust for the confounding factors. Treatment effects were estimated using multivariable logistic regression analysis, including PS. [RESULTS] A total of 5, 838 patients were included in this study. The crude 30-day mortality rates were 2.4% (8/334) and 1.7% (96/5, 504) in the FloTrac and PAC groups, respectively. After PS matching, the ORs for 30-day all-cause mortality, in-hospital mortality after PAC placement (vs. FloTrac) were 0.36 (95% CI: 0.05–2.37; p = 0.28) and 0.59 (95% CI: 0.16–2.20; p = 0.43), respectively. The amount of dobutamine was larger in the PAC group (281 ± 31 mg vs 155 ± 19 mg; p < 0.001). There were no significant differences in the amounts of other inotropes, the volume of fluids, or blood transfusions. [CONCLUSIONS] The association between PAC (with venous oxygen saturation monitoring) and mortality in patients who underwent elective cardiac surgeries was unclear compared to FloTrac (with central venous oxygen saturation monitoring). Additional investigation is needed to evaluate the benefits of PAC-specific hemodynamic parameters in this population.en
dc.language.isoeng-
dc.publisherSociety for Clinical Epidemiologyen
dc.publisher.alternative日本臨床疫学会ja
dc.rights© 2022 Society for Clinical Epidemiologyen
dc.rightsThis article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.en
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectpulmonary artery catheteren
dc.subjectarterial pressure wave analysisen
dc.subjectVigileo/FloTrac systemen
dc.subjectreal-world dataen
dc.titleHemodynamic Monitoring Using a Pulmonary Artery Catheter Versus the Vigileo/FloTrac System during Elective Cardiac Surgery Based on Real-world Data in Japanen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleAnnals of Clinical Epidemiologyen
dc.identifier.volume4-
dc.identifier.issue3-
dc.identifier.spage81-
dc.identifier.epage91-
dc.relation.doi10.37737/ace.22011-
dc.textversionpublisher-
dc.identifier.pmid38504946-
dcterms.accessRightsopen access-
dc.identifier.eissn2434-4338-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス Creative Commons