ダウンロード数: 27

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
acm2.13827.pdf4.05 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorOgawa, Ayakaen
dc.contributor.authorNakamura, Mitsuhiroen
dc.contributor.authorIramina, Hirakuen
dc.contributor.authorYoshimura, Michioen
dc.contributor.authorMizowaki, Takashien
dc.contributor.alternative小川, 彩加ja
dc.contributor.alternative中村, 光宏ja
dc.contributor.alternative伊良皆, 拓ja
dc.contributor.alternative吉村, 通央ja
dc.contributor.alternative溝脇, 尚志ja
dc.date.accessioned2024-02-16T02:08:27Z-
dc.date.available2024-02-16T02:08:27Z-
dc.date.issued2023-02-
dc.identifier.urihttp://hdl.handle.net/2433/287021-
dc.description.abstract[Purpose] The purpose of this study was to demonstrate the potential utility of cone-beam computed tomography (CBCT)-guided online adaptive radiotherapy (ART) under end-exhalation breath-hold (EE-BH) conditions for pancreatic cancer (PC). [Methods] Eleven PC patients who underwent 15-fraction volumetric-modulated arc therapy under EE-BH conditions were included. Planning CT images and daily 165 CBCT images were imported into a dedicated treatment planning system. The prescription dose was set to 48 Gy in 15 fractions. The reference plan was automatically generated along with predefined clinical goals. After segmentation was completed on CBCT images, two different plans were generated: One was an adapted (ADP) plan in which re-optimization was performed on the anatomy of the day, and the other was a scheduled (SCH) plan, which was the same as the reference plan. The dose distributions calculated using the synthetic CT created from both planning CT and CBCT were compared between the two plans. Independent calculation-based quality assurance was also performed for the ADP plans, with a gamma passing rate of 3%/3 mm. [Results] All clinical goals were successfully achieved during the reference plan generation. Of the 165 sessions, gross tumor volume D98% and clinical target volume D98% were higher in 100 (60.1%) and 122 (74.0%) ADP fractions. In each fraction, the V3 Gy < 1 cm³ of the stomach and duodenum was violated in 47 (28.5%) and 48 (29.1%), respectively, of the SCH fractions, whereas no violations were observed in the ADP fractions. There were statistically significant differences in the dose–volume indices between the SCH and ADP fractions (p < 0.05). The gamma passing rates were above 95% in all ADP fractions. [Conclusions] The CBCT-guided online ART under EE-BH conditions successfully reduced the dose to the stomach and duodenum while maintaining target coverage.en
dc.language.isoeng-
dc.publisherWileyen
dc.publisherThe American Association of Physicists in Medicineen
dc.rights© 2022 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine.en
dc.rightsThis is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.en
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/-
dc.subjectCBCT-guided adaptive radiotherapyen
dc.subjectdosimetric analysisen
dc.subjectindependent calculation-based QAen
dc.subjectpancreatic canceren
dc.titlePotential utility of cone‐beam CT‐guided adaptive radiotherapy under end‐exhalation breath‐hold conditions for pancreatic canceren
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleJournal of Applied Clinical Medical Physicsen
dc.identifier.volume24-
dc.identifier.issue2-
dc.relation.doi10.1002/acm2.13827-
dc.textversionpublisher-
dc.identifier.artnume13827-
dc.identifier.pmid36316795-
dcterms.accessRightsopen access-
dc.identifier.eissn1526-9914-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス Creative Commons