dc.contributor.author | Yamamoto, Akinari | en |
dc.contributor.author | Miyata, Manabu | en |
dc.contributor.author | Tsujikawa, Akitaka | en |
dc.contributor.alternative | 山本, 昭成 | ja |
dc.contributor.alternative | 宮田, 学 | ja |
dc.contributor.alternative | 辻川, 明孝 | ja |
dc.date.accessioned | 2024-11-06T04:43:39Z | - |
dc.date.available | 2024-11-06T04:43:39Z | - |
dc.date.issued | 2024-03-08 | - |
dc.identifier.uri | http://hdl.handle.net/2433/290165 | - |
dc.description.abstract | Internal limiting membrane (ILM) peeling requires a delicate handling technique. It is also important that ophthalmologists can use the ILM forceps handle of their preference. This study objectively and subjectively evaluated the handling of the novel Finesse Reflex Handle (Reflex) in comparison with that of a conventional handle. The force required to close the forceps tips, evaluated using a digital force gauge, was significantly lesser for Reflex than for the conventional handle (3.14 ± 0.09 N vs. 3.84 ± 0.06 N, P < 0.001). Twenty-one ophthalmologists with various levels of experience answered a questionnaire after using both handles, and the total questionnaire score for Reflex was higher than that for the conventional handle (35.0 ± 3.7 vs. 30.0 ± 6.9, P = 0.01). Furthermore, the duration of experience as an ophthalmologist was negatively correlated with the vertical motion, assessed by video analysis, for the conventional handle (P = 0.02, r = - 0.50) but not for Reflex (P = 0.26). In conclusion, objective and subjective analyses revealed that compared with the conventional handle, the novel Reflex handle had more favourable handling characteristics. Most ophthalmologists preferred the handling of Reflex. Reflex may compensate for a lack of surgical experience. | en |
dc.language.iso | eng | - |
dc.publisher | Springer Nature | en |
dc.rights | © The Author(s) 2024 | en |
dc.rights | This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. | en |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | - |
dc.subject | Surgery | en |
dc.subject | Techniques and instrumentation | en |
dc.title | Ophthalmologists' assessment of the handling characteristics of the novel Finesse Reflex Handle in comparison to those of a conventional handle | en |
dc.type | journal article | - |
dc.type.niitype | Journal Article | - |
dc.identifier.jtitle | Scientific Reports | en |
dc.identifier.volume | 14 | - |
dc.relation.doi | 10.1038/s41598-024-56501-8 | - |
dc.textversion | publisher | - |
dc.identifier.artnum | 5736 | - |
dc.identifier.pmid | 38459107 | - |
dcterms.accessRights | open access | - |
dc.identifier.eissn | 2045-2322 | - |