このアイテムのアクセス数: 14

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
EB.S474100.pdf1.76 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorShimada, Ayakaen
dc.contributor.authorSuda, Kenjien
dc.contributor.authorNakano, Erien
dc.contributor.authorTagawa, Mihoen
dc.contributor.authorMiyata, Manabuen
dc.contributor.authorKashii, Satoshien
dc.contributor.authorHinoda, Takuyaen
dc.contributor.authorFushimi, Yasutakaen
dc.contributor.authorKimura, Kimitoshien
dc.contributor.authorNishigori, Ryuseien
dc.contributor.authorAhn, Sinyeoben
dc.contributor.authorGrinstead, Johnen
dc.contributor.authorTsujikawa, Akitakaen
dc.contributor.alternative島田, 文香ja
dc.contributor.alternative須田, 謙史ja
dc.contributor.alternative中野, 絵梨ja
dc.contributor.alternative田川, 美穂ja
dc.contributor.alternative宮田, 学ja
dc.contributor.alternative柏井, 聡ja
dc.contributor.alternative日野田, 卓也ja
dc.contributor.alternative伏見, 育崇ja
dc.contributor.alternative木村, 公俊ja
dc.contributor.alternative錦織, 隆成ja
dc.contributor.alternative辻川, 明孝ja
dc.date.accessioned2024-11-28T06:28:24Z-
dc.date.available2024-11-28T06:28:24Z-
dc.date.issued2024-
dc.identifier.urihttp://hdl.handle.net/2433/290608-
dc.description.abstractPurpose: To evaluate the use of delay alternating with nutation for tailored excitation-prepared T1-weighted turbo spin echo (DANTE T1-SPACE) imaging for diagnosing optic neuritis and to analyze its correlation with clinical findings before and after treatment. Patients and Methods: Patients diagnosed with optic neuritis or non-arteritic anterior ischemic optic neuropathy (NA-AION) were evaluated at the Ophthalmology Department of Kyoto University Hospital. All patients underwent magnetic resonance (MR) studies before treatment initiation and ophthalmic examinations before and after treatment. Three ophthalmologists independently reviewed the MR scans for abnormalities. The magnetic resonance imaging (MRI) assessments included post-contrast DANTE T1-SPACE, post-contrast volumetric interpolated breath-hold examination (VIBE), and short T1 inversion recovery (STIR) scans. The presence of abnormalities in each sequence was determined. Results: Of 36 eyes from 30 patients, 21 eyes from 17 patients were diagnosed with optic neuritis, and 15 eyes from 13 patients were diagnosed with NA-AION. DANTE T1-SPACE sequences showed better sensitivity for detecting optic neuritis than STIR sequences (100% vs 67%, p = 0.009). VIBE images did not confirm enhancement of lesions in some cases with optic neuritis. No differences were observed among the sequences for NA-AION. Lesion length evaluated by DANTE T1-SPACE sequences was associated with circumpapillary retinal nerve fiber layer thickness at the initial visit, eye pain, and the time interval from symptom onset to MRI scan. Conclusion: Contrast-enhanced DANTE T1-SPACE was better than other sequences of MRI for diagnosing optic neuritis.en
dc.language.isoeng-
dc.publisherDove Pressen
dc.rights© 2024 The Author(s).en
dc.rightsThis work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms. php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.en
dc.rights.urihttps://creativecommons.org/licenses/by-nc/3.0/-
dc.subjectOptic neuritisen
dc.subjectmagnetic resonance imagingen
dc.subjectretinal nerve fiber layeren
dc.subjectvisual field testen
dc.titleAccuracy of Diagnosing Optic Neuritis Using DANTE T1-SPACE Imagingen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleEye and Brainen
dc.identifier.volume16-
dc.identifier.spage65-
dc.identifier.epage73-
dc.relation.doi10.2147/EB.S474100-
dc.textversionpublisher-
dc.identifier.pmid39493624-
dcterms.accessRightsopen access-
dc.identifier.eissn1179-2744-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス Creative Commons