このアイテムのアクセス数: 21

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
2024.5.JNS24174.pdf6.47 MBAdobe PDF見る/開く
タイトル: Efficacy of high-resolution vessel wall MRI in the postoperative assessment of intracranial aneurysms following flow diversion treatment.
著者: Matsukawa, So
Ishii, Akira
Fushimi, Yasutaka
Grinstead, John
Ahn, Sinyeob
Kikuchi, Takayuki
Yamada, Hiroki
Okawa, Masakazu
Yamao, Yukihiro
Abekura, Yu
Sasaki, Natsuhi
Tsuji, Hirofumi
Akiyama, Ryo
Arakawa, Yoshiki
著者名の別形: 松川, 爽
石井, 暁
伏見, 育崇
菊池, 隆幸
山田, 浩貴
大川, 将和
山尾, 幸広
安部倉, 友
佐々木, 夏一
辻, 博文
秋山, 亮
荒川, 芳輝
キーワード: aneurysm
flow diversion treatment
vessel wall imaging
VW-MRI
delay alternating with nutation for tailored excitation
DANTE
vascular disorders
発行日: Jan-2025
出版者: American Association of Neurological Surgeons
誌名: Journal of Neurosurgery
巻: 142
号: 1
開始ページ: 88
終了ページ: 97
抄録: OBJECTIVE: Certain patients must undergo frequent postoperative digital subtraction angiography (DSA) after flow diversion (FD) therapy. No imaging modality with an efficacy comparable to that of DSA has been established. This study was conducted to determine the efficacy of contrast-enhanced delay alternating with nutation for tailored excitation (DANTE) T1-sampling perfection with application-optimized contrasts by using different flip angle evolution (SPACE), a high-resolution vessel wall magnetic resonance imaging technique for evaluating the occlusion status of intracranial aneurysms after FD treatment, with DSA serving as the reference standard. METHODS: This retrospective study included 23 patients with 26 aneurysms who had undergone FD treatment between April 2016 and May 2022. Contrast-enhanced DANTE T1-SPACE and DSA were performed as postoperative follow-up imaging studies at 45 time points, both in the same period. The agreement rates for aneurysm occlusion status in the 45 imaging studies were examined. RESULTS: Contrast-enhanced DANTE T1-SPACE had a sensitivity and specificity of 96.3% (26/27) and 83.3% (15/18), respectively, for detecting aneurysm remnants. Overall, 91.1% (41/45) of findings detected on contrast-enhanced DANTE T1-SPACE were consistent with those on DSA. The findings detected on contrast-enhanced DANTE T1-SPACE were completely consistent with those of intraaneurysmal residual blood flow identified on DSA or high-resolution cone-beam computed tomography images in 74.1% (20/27) of the examinations that showed incomplete occlusion on DSA. Furthermore, parent artery status after FD treatment on contrast-enhanced DANTE T1-SPACE was consistent with that observed on DSA in 97.8% (44/45) of examinations. CONCLUSIONS: Contrast-enhanced DANTE T1-SPACE is a very useful option in the follow-up of aneurysms after FD treatment.
著作権等: © 2024 The authors
CC BY-NC-ND 4.0
URI: http://hdl.handle.net/2433/291100
DOI(出版社版): 10.3171/2024.5.JNS24174
PubMed ID: 39213673
出現コレクション:学術雑誌掲載論文等

アイテムの詳細レコードを表示する

Export to RefWorks


出力フォーマット 


このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス Creative Commons