このアイテムのアクセス数: 22

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
s11604-024-01717-x.pdf1.1 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorOtani, Sayoen
dc.contributor.authorFushimi, Yasutakaen
dc.contributor.authorOkuchi, Sachien
dc.contributor.authorSakata, Akihikoen
dc.contributor.authorYamamoto, Takayukien
dc.contributor.authorNakajima, Satoshien
dc.contributor.authorWang, Yangen
dc.contributor.authorIkeda, Satoshien
dc.contributor.authorIto, Shuichien
dc.contributor.authorYasumura, Sumikaen
dc.contributor.authorTakada, Shigekien
dc.contributor.authorSano, Noritakaen
dc.contributor.authorUeno, Kentaroen
dc.contributor.authorUrushibata, Yutaen
dc.contributor.authorZhou, Kunen
dc.contributor.authorArakawa, Yoshikien
dc.contributor.authorNakamoto, Yujien
dc.date.accessioned2025-03-03T02:36:54Z-
dc.date.available2025-03-03T02:36:54Z-
dc.date.issued2024-12-28-
dc.identifier.urihttp://hdl.handle.net/2433/292279-
dc.description.abstract[Purpose]To compare quantitative values and image quality between single-shot echo-planar imaging (SS-EPI) diffusion-weighted imaging (DWI) and two-dimensional turbo gradient- and spin-echo DWI with non-Cartesian BLADE trajectory (TGSE-BLADE DWI) in patients with epidermoid cyst. [Methods]Patients with epidermoid cyst who underwent both SS-EPI DWI and TGSE-BLADE DWI were included in this study. Two raters placed ROIs encircling the entire epidermoid cyst on SS-EPI DWI, and then on TGSE-BLADE DWI. Apparent diffusion coefficient (ADC) of the epidermoid cyst was measured within each ROI, then the intraclass correlation coefficient (ICC) between raters was obtained for each DWI. The areas of ROIs placed by the two raters were measured and compared using the Dice coefficient. In the selected slice analysis, one rater selected the most appropriate slice and carefully placed the ROIs slightly smaller than the epidermoid outline to avoid artifacts. Image quality analysis was assessed qualitatively for geometric distortion, susceptibility artifacts, lesion conspicuity, and diagnostic confidence. ADCs for both DWI techniques were compared with theoretical values derived from the diffusion phantom. [Results]Twenty patients with epidermoid cyst were included in this study. The ICC of ADC measured by the two raters for TGSE-BLADE (0.80) was higher than that for SS-EPI (0.59). Dice coefficient of ROI areas was significantly higher with TGSE-BLADE (0.78) than with SS-EPI (0.71, P = 0.007). Selected slice analysis showed that the ADC of epidermoid cyst was significantly higher with TGSE-BLADE DWI than with SS-EPI DWI (P < 0.001). ADCs measured from carefully selected ROIs avoiding artifacts with the two techniques correlated positively (r = 0.87, P < 0.001; ICC 0.75). TGSE-BLADE DWI rated better for image quality than SS-EPI DWI according to all raters. ICCs of measured ADC and theoretical ADCs exceeded 0.99 for both techniques. [Conclusions]TGSE-BLADE DWI appears more suitable than SS-EPI DWI for evaluating epidermoid cyst.en
dc.language.isoeng-
dc.publisherSpringer Natureen
dc.rights© The Author(s) 2024en
dc.rightsThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are cincluded in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.en
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/-
dc.subjectEpidermoid cysten
dc.subjectDiffusion-weighted imagingen
dc.subjectTurbo gradient- and spin-echo DWI with non-Cartesian BLADE trajectoryen
dc.subjectSingle-shot echo-planar imagingen
dc.subjectTGSEen
dc.titleComparison of DWI techniques in patients with epidermoid cyst: TGSE-BLADE DWI vs. SS-EPI DWIen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleJapanese journal of radiologyen
dc.relation.doi10.1007/s11604-024-01717-x-
dc.textversionpublisher-
dc.identifier.pmid39730930-
dcterms.accessRightsopen access-
dc.identifier.pissn1867-1071-
dc.identifier.eissn1867-108X-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス Creative Commons