このアイテムのアクセス数: 7
このアイテムのファイル:
ファイル | 記述 | サイズ | フォーマット | |
---|---|---|---|---|
j.radcr.2025.03.052.pdf | 2.27 MB | Adobe PDF | 見る/開く |
完全メタデータレコード
DCフィールド | 値 | 言語 |
---|---|---|
dc.contributor.author | Toda, Daiki | en |
dc.contributor.author | Nakajima, Satoshi | en |
dc.contributor.author | Fushimi, Yasutaka | en |
dc.contributor.author | Kitano, Takaaki | en |
dc.contributor.author | Tanji, Masahiro | en |
dc.contributor.author | Mineharu, Yohei | en |
dc.contributor.author | Takeuchi, Yasuhide | en |
dc.contributor.author | Haga, Hironori | en |
dc.contributor.author | Arakawa, Yoshiki | en |
dc.contributor.author | Nakamoto, Yuji | en |
dc.date.accessioned | 2025-06-03T01:51:59Z | - |
dc.date.available | 2025-06-03T01:51:59Z | - |
dc.date.issued | 2025-07 | - |
dc.identifier.uri | http://hdl.handle.net/2433/294475 | - |
dc.description.abstract | Corticosteroids are widely used to manage peritumoral edema and associated neurological deficits in patients with brain tumors. We describe the case of a 71-year-old male patient with glioblastoma in which contrast enhancement decreased on radiographic imaging following corticosteroid administration, which has been reported previously in only 9 cases. This report aims to discuss radiographic changes in glioblastoma (density on computed tomography and diffusion capability on diffusion-weighted magnetic resonance imaging, in addition to enhancement on contrast-enhanced T1-weighted magnetic resonance imaging) following steroid administration and also following steroid discontinuation. | en |
dc.language.iso | eng | - |
dc.publisher | Elsevier BV | en |
dc.rights | © 2025 The Authors. Published by Elsevier Inc. on behalf of University of Washington. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/) | en |
dc.subject | Glioblastoma | en |
dc.subject | Corticosteroid | en |
dc.subject | Contrast enhancement | en |
dc.subject | Density | en |
dc.subject | Diffusion capability | en |
dc.title | Glioblastoma with markedly reduced contrast enhancement after corticosteroid administration: Increased density and reduced diffusion capability are noteworthy | en |
dc.type | journal article | - |
dc.type.niitype | Journal Article | - |
dc.identifier.jtitle | Radiology case reports | en |
dc.identifier.volume | 20 | - |
dc.identifier.issue | 7 | - |
dc.identifier.spage | 3186 | - |
dc.identifier.epage | 3190 | - |
dc.relation.doi | 10.1016/j.radcr.2025.03.052 | - |
dc.textversion | publisher | - |
dc.identifier.pmid | 40292124 | - |
dcterms.accessRights | open access | - |
dc.identifier.eissn | 1930-0433 | - |
出現コレクション: | 学術雑誌掲載論文等 |

このリポジトリに保管されているアイテムはすべて著作権により保護されています。