このアイテムのアクセス数: 1304
完全メタデータレコード
DCフィールド | 値 | 言語 |
---|---|---|
dc.contributor.author | 三井, 政子 | ja |
dc.contributor.alternative | Mitsui, Masako | en |
dc.contributor.transcription | ミツイ, マサコ | ja-Kana |
dc.date.accessioned | 2007-12-18T06:27:38Z | - |
dc.date.available | 2007-12-18T06:27:38Z | - |
dc.date.issued | 1983 | - |
dc.identifier.issn | 02867850 | - |
dc.identifier.uri | http://hdl.handle.net/2433/49282 | - |
dc.description.abstract | Finger-tip plethysmogram and blood pressure were measured in 15 parturient women during delivery, 4 times during the first stage, 3 times during the second stage and 10 times during the third stage. Pulse-wave shape, pulse-wave height, blood pressure and heart rate were compared between supine position and half-sitting position. In the supine, pulse-wave height decreased gradually after the onset of labor pains, showing the lowest value of 2.3±0.2 mV/V at the end of bearing down labor. During the interval of the pain, pulse-wave height was always higher than that of labor pain. At the middle phase of the first stage when cervical dilatation was 6cm, pulse-wave height exhibited a relatively high value of 9.4±1.3 mV/V. In the half-sitting position, however, there was no remarkable variation in pulse-wave height. At 60 minutes after delivery of the placenta the pulse-wave height was 4.8±1.2 mV/V, and it also remained unchanged for the next 1 hour. In the second stage, the heart rate increased to twice that at the beginning of the first stage in supine position, while the increase remained only 25% in half-sitting position. After the delivery of the placenta, the heart rate decreased remarkably and returned to the control value by 2 hours after delivery. These data indicate that the cardiac load during labor was smaller in half-sitting position than in supine position. In conclusion, the delivery in half-sitting position is recommended. | en |
dc.language.iso | jpn | - |
dc.publisher | 京都大学医療技術短期大学部 | ja |
dc.subject.ndc | 492 | - |
dc.title | 指尖容積脈波による母体循環動態からみた分娩時の安楽体位 | ja |
dc.title.alternative | <Originals> The Comfortable Position of Parturient Women Evaluated by Finger-Tip Plethysmogram and Blood Pressure | en |
dc.type | departmental bulletin paper | - |
dc.type.niitype | Departmental Bulletin Paper | - |
dc.identifier.ncid | AN00060677 | - |
dc.identifier.jtitle | 京都大学医療技術短期大学部紀要 | ja |
dc.identifier.volume | 3 | - |
dc.identifier.spage | 64 | - |
dc.identifier.epage | 69 | - |
dc.textversion | publisher | - |
dc.sortkey | 10 | - |
dcterms.accessRights | open access | - |
dc.identifier.pissn | 0286-7850 | - |
dc.identifier.jtitle-alternative | Annual reports of the College of Medical Technology, Kyoto University | en |
出現コレクション: | 第3号 |

このリポジトリに保管されているアイテムはすべて著作権により保護されています。