このアイテムのアクセス数: 482

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
soa023_057.pdf643.15 kBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorKitazawa, Shigeyoshien
dc.contributor.authorDantsuji, Masatakeen
dc.contributor.authorDoshita, Shujien
dc.contributor.alternativeキタザワ, シゲヨシja
dc.contributor.alternativeダンツジ, マサタケja
dc.contributor.alternativeドウシタ, シュウジja
dc.contributor.transcriptionキタザワ, シゲヨシja-Kana
dc.contributor.transcriptionダンツジ, マサタケja-Kana
dc.contributor.transcriptionドウシタ, シュウジja-Kana
dc.date.accessioned2008-04-22T05:24:45Z-
dc.date.available2008-04-22T05:24:45Z-
dc.date.issued1989-
dc.identifier.issn0300-1067-
dc.identifier.urihttp://hdl.handle.net/2433/52493-
dc.description.abstractCochlear implant systems have been developed and used for many patients, however, the processing system is still imperfect in transferring speech information. Usually, processing is evaluated with the cooperation of implanted patients, but this implies difficulties and limits the application. Obviously the speech processor needs to be improved because it extracts only limited speech features. In order to accelerate improvements, we developed acoustic simulator hardware which is intended to imitate the stimulation received by implanted patients. It consists of a set of active filters with operational amplifier circuits, like the original speech processor. Hard-wired analog circuits are used to achieve real time examination on various sources of speech material. The acoustic process and electro-neuro-physiological process in action around the electrode implanted into the cochlea and haircell nerve were with band pass filters and stimulation pulse trains which are amplitude modulated. This system has been evaluated under several conditions, such as monosyllables, words, and sentences. Comparison with other reports, our results have shown that this hardware simulation approximately matches the articulation score of implanted patients. This simulator developed here provides a useful tool for evaluation of acoustic processing and parameter coding schemes for cochlear implant systems.en
dc.language.isoeng-
dc.publisherINSTITUTION FOR PHONETIC SCIENCES UNIVERSITY OF KYOTOen
dc.subject.ndc801.1-
dc.titleHardware Simulation of Cochlear Implant Systemen
dc.typedepartmental bulletin paper-
dc.type.niitypeDepartmental Bulletin Paper-
dc.identifier.ncidAN00034779-
dc.identifier.jtitle音声科学研究ja
dc.identifier.volume23-
dc.identifier.spage57-
dc.identifier.epage68-
dc.textversionpublisher-
dc.sortkey07-
dcterms.accessRightsopen access-
dc.identifier.pissn0300-1067-
dc.identifier.jtitle-alternativeStudia phonologicaen
出現コレクション:Vol.23

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。