このアイテムのアクセス数: 451

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
j.fusengdes.2012.02.071.pdf630.19 kBAdobe PDF見る/開く
タイトル: Vacuum sieve tray for tritium extraction from liquid Pb–17Li
著者: Okino, Fumito
Noborio, Kazuyuki
Yamamoto, Yasushi
Konishi, Satoshi  KAKEN_id
著者名の別形: 興野, 文人
キーワード: Vacuum-sieve-tray
Droplet
Pb–17Li
Diffusion
Plateau-Rayleigh-Instability (P.R.I.)
Surface-tension
発行日: Aug-2012
出版者: Elsevier B.V.
誌名: Fusion Engineering and Design
巻: 87
号: 7-8
開始ページ: 1014
終了ページ: 1018
抄録: Formation of droplet of liquid Li–17Pb released from a nozzle into vacuum was studied for the evaluation of the feasibility as a tritium extraction process. Size of droplets formed from the nozzles was estimated by theoretical and experimental methods. For the theoretical estimation, the non-dimensional comparison of the physical bulk property of liquid Pb–17Li with water (H2O) at ambient temperature was applied. It was found to be reasonable to apply the Plateau-Rayleigh-Instability theory for the droplet size formula of the fluid Pb–17Li for the nozzle diameter 0.4 mm–1.0 mm, temperature 400 °C–500 °C, at initial velocity of 3 m/s. The experimental results of the droplet size showed good agreement with the theory. This device was used for the parametric study of extraction of deuterium during their free fall in vacuum. The scaling of the device suggests the engineering feasibility of the process.
著作権等: © 2012 Elsevier B.V.
この論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。
This is not the published version. Please cite only the published version.
URI: http://hdl.handle.net/2433/160052
DOI(出版社版): 10.1016/j.fusengdes.2012.02.071
出現コレクション:学術雑誌掲載論文等

アイテムの詳細レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。