Downloads: 195

Files in This Item:
File Description SizeFormat 
1.4794506.pdf1.94 MBAdobe PDFView/Open
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMukumoto, Nobutakaja
dc.contributor.authorNakamura, Mitsuhiroja
dc.contributor.authorSawada, Akiraja
dc.contributor.authorSuzuki, Yasunobuja
dc.contributor.authorTakahashi, Kunioja
dc.contributor.authorMiyabe, Yukija
dc.contributor.authorKaneko, Shujija
dc.contributor.authorMizowaki, Takashija
dc.contributor.authorKokubo, Masakija
dc.contributor.authorHiraoka, Masahiroja
dc.contributor.alternative中村, 光宏ja
dc.date.accessioned2014-09-24T05:52:16Z-
dc.date.available2014-09-24T05:52:16Z-
dc.date.issued2013-04ja
dc.identifier.issn0094-2405ja
dc.identifier.urihttp://hdl.handle.net/2433/189832-
dc.description.abstract[Purpose] To verify the accuracy of an infrared (IR) marker-based dynamic tumor-tracking irradiation system (IR tracking) using the gimbaled x-ray head of the Vero4DRT (MHI-TM2000). Conclusions: Positional tracking errors correlated strongly with 4D-modeling errors in IR tracking. Thus, the accuracy of the 4D model must be verified before treatment, and margins are required to compensate for the 4D-modeling error [Conclusions] Positional tracking errors correlated strongly with 4D-modeling errors in IR tracking. Thus, the accuracy of the 4D model must be verified before treatment, and margins are required to compensate for the 4D-modeling error.ja
dc.format.mimetypeapplication/pdfja
dc.language.isoengja
dc.publisherAmerican Association of Physicists in Medicineja
dc.rights© 2013 American Association of Physicists in Medicineja
dc.rightsこの論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。This is not the published version. Please cite only the published version.ja
dc.subject.meshEquipment Designja
dc.subject.meshEquipment Failure Analysisja
dc.subject.meshFiducial Markersja
dc.subject.meshHumansja
dc.subject.meshImaging, Three-Dimensional/instrumentationja
dc.subject.meshInfrared Rays/diagnostic useja
dc.subject.meshNeoplasms/diagnosisja
dc.subject.meshNeoplasms/radiotherapyja
dc.subject.meshPattern Recognition, Automated/methodsja
dc.subject.meshPhantoms, Imagingja
dc.subject.meshRadiotherapy, Image-Guided/instrumentationja
dc.subject.meshReproducibility of Resultsja
dc.subject.meshSensitivity and Specificityja
dc.subject.meshThermography/instrumentationja
dc.subject.meshTomography, X-Ray Computed/instrumentationja
dc.titleAccuracy verification of infrared marker-based dynamic tumor-tracking irradiation using the gimbaled x-ray head of the Vero4DRT (MHI-TM2000).ja
dc.type.niitypeJournal Articleja
dc.identifier.ncidAA00727671ja
dc.identifier.jtitleMedical physicsja
dc.identifier.volume40ja
dc.identifier.issue4ja
dc.relation.doi10.1118/1.4794506ja
dc.textversionauthorja
dc.identifier.artnum41706ja
dc.identifier.pmid23556876ja
Appears in Collections:Journal Articles

Show simple item record

Export to RefWorks


Export Format: 


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.