このアイテムのアクセス数: 305
このアイテムのファイル:
ファイル | 記述 | サイズ | フォーマット | |
---|---|---|---|---|
j.egypro.2016.05.051.pdf | 329.99 kB | Adobe PDF | 見る/開く |
完全メタデータレコード
DCフィールド | 値 | 言語 |
---|---|---|
dc.contributor.author | Daito, I. | en |
dc.contributor.author | Ohgaki, H. | en |
dc.contributor.author | Suliman, G. | en |
dc.contributor.author | Iancu, V. | en |
dc.contributor.author | Ur, C. A. | en |
dc.contributor.author | Iovea, M. | en |
dc.contributor.alternative | 大垣, 英明 | ja |
dc.date.accessioned | 2016-08-08T02:58:12Z | - |
dc.date.available | 2016-08-08T02:58:12Z | - |
dc.date.issued | 2016-06 | - |
dc.identifier.issn | 1876-6102 | - |
dc.identifier.uri | http://hdl.handle.net/2433/216246 | - |
dc.description | CoE on Sustainable Energy System (Thai-Japan), Faculty of Engineering, Rajamangala University of Technology Thanyaburi (RMUTT), Thailand | en |
dc.description.abstract | Non-destructive inspection carried out by using nuclear resonances excited by an MeV energy region gamma ray is a promising method. The high penetrability of MeV gamma ray of nuclear resonant energy makes possible the detection of nuclides surrounded by massive materials. As an application of this method, computed tomography imaging of nuclear distribution inside objects can be reconstructed from transmission factor of gamma rays. We have studied the image reconstruction of the nuclear distribution using Monte-Carlo simulations to estimate the gamma-ray transmission factor assuming the ELI-NP facility where about 3 order higher intensity of quasi-monoenergetic gamma rays will be available. | en |
dc.format.mimetype | application/pdf | - |
dc.language.iso | eng | - |
dc.publisher | Elsevier Ltd. | en |
dc.rights | © 2016 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license(http://creativecommons.org/licenses/by-nc-nd/4.0/). | en |
dc.subject | Laser Compton Scattering | en |
dc.subject | Nuclear Resonance Fluorescence | en |
dc.subject | non-destructive inspection | en |
dc.subject | Computed Tomography | en |
dc.title | Simulation Study on Computer Tomography Imaging of Nuclear Distribution by Quasi Monoenergetic Gamma Rays with Nuclear Resonance Fluorescence: case study for ELI-NP application | en |
dc.type | journal article | - |
dc.type.niitype | Journal Article | - |
dc.identifier.jtitle | Energy Procedia | en |
dc.identifier.volume | 89 | - |
dc.identifier.spage | 389 | - |
dc.identifier.epage | 394 | - |
dc.relation.doi | 10.1016/j.egypro.2016.05.051 | - |
dc.textversion | publisher | - |
dcterms.accessRights | open access | - |
出現コレクション: | 学術雑誌掲載論文等 |

このリポジトリに保管されているアイテムはすべて著作権により保護されています。