dc.description.abstractA damage localization method based on the time reversal focusing of the mode-converted scattered Lamb wave is proposed for plate structures with a non-symmetric defect in the thickness direction. Dual transducers are attached symmetrically on the upper and lower surfaces of the plate to selectively emit and receive the lowest-order symmetric (S0) and antisymmetric (A0) modes. The localization of damage is achieved by the numerical time-reversed (TR) simulation of the mode-converted Lamb wave generated at the defect. To investigate the validity of the proposed method, the signals of the Lamb waves in a plate with a partial-thickness notch are numerically simulated by the three-dimensional elastodynamic finite integration technique (EFIT). When the S0 mode is emitted in the damaged plate, not only the S0 mode is scattered but also the A0 mode is generated due to mode conversion at the notch. Similar mode conversion behavior is confirmed when the A0 mode is emitted. The time reversal of the mode-converted scattered Lamb waves creates focused spots at the damage location without using baseline data for the undamaged plate. The proposed method reduces the magnitude of the artifacts compared to the time reversal of the non-mode-converted Lamb wave, and yields the focused spot whose size is associated with the size of the notch and the half wavelength of the time-reversed wave mode. Furthermore, the proposed method is applied to a plate with a notch-type defect adjacent to an a priori known through-thickness hole, demonstrating the damage localization in a relatively complicated structure.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherElsevier BVen
dc.rights© <2019>. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/.en
dc.rightsThe full-text file will be made open to the public on 01 January 2021 in accordance with publisher's 'Terms and Conditions for Self-Archiving'.en
dc.rightsこの論文は出版社版でありません。引用の際には出版社版をご確認ご利用ください。ja
dc.rightsThis is not the published version. Please cite only the published version.en
dc.subjectDamage localizationen
dc.subjectTime reversalen
dc.subjectLamb waveen
dc.subjectMode conversionen
dc.titleDamage localization method for plates based on the time reversal of the mode-converted Lamb wavesen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleUltrasonicsen
dc.identifier.volume91-
dc.identifier.spage19-
dc.identifier.epage29-
dc.relation.doi10.1016/j.ultras.2018.07.007-
dc.textversionauthor-
dc.addressDepartment of Mechanical Engineering, College of Science and Engineering, Ritsumeikan Universityen
dc.addressDepartment of Aeronautics and Astronautics, Graduate School of Engineering, Kyoto Universityen
dc.addressDepartment of Mechanical Engineering, College of Science and Engineering, Ritsumeikan Universityen
dc.identifier.pmid30031966-
dcterms.accessRightsopen access-
datacite.date.available2021-01-01-
datacite.awardNumber262190-
jpcoar.funderName日本学術振興会ja
jpcoar.funderName.alternativeJapan Society for the Promotion of Science (JSPS)en
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。