このアイテムのアクセス数: 198

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
bunsekikagaku.62.979.pdf563.3 kBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.author亀田, 貴之ja
dc.contributor.author片山, 裕規ja
dc.contributor.author後藤, 知子ja
dc.contributor.author鳥羽, 陽ja
dc.contributor.author唐, 寧ja
dc.contributor.author早川, 和一ja
dc.contributor.alternativeKAMEDA, Takayukien
dc.contributor.alternativeKATAYAMA, Yukien
dc.contributor.alternativeGOTO, Tomokoen
dc.contributor.alternativeTORIBA, Akiraen
dc.contributor.alternativeTANG, Ningen
dc.contributor.alternativeHAYAKAWA, Kazuichien
dc.date.accessioned2019-03-27T06:40:19Z-
dc.date.available2019-03-27T06:40:19Z-
dc.date.issued2013-11-05-
dc.identifier.issn0525-1931-
dc.identifier.urihttp://hdl.handle.net/2433/237720-
dc.description.abstractA simple and sensitive method for measuring quinoid polycyclic aromatic hydrocarbons (PAHQs) in soluble organic fraction (SOF) of airborne particles based on two-dimensional high-performance liquid chromatography (HPLC) with fluorescence detection was established. The system involves a reversed phase column with naphtylethyl groups bonded silica packing material for sample clean-up, a 6-port switching valve, an ODS column for trapping the fraction containing PAHQs, a reversed phase column with cholesteryl groups bonded silica packing material for sample separation, and a Pt-Rh catalytic column for the reduction of PAHQs to a corresponding fluorescent compound. The accuracy of the assay, as applied to airborne particulate sample extracts spiked with known amounts of PAHQs were 91 – 107%. The detection limits were 19 to 2000 fmol per injection (signal-to-noise ratio = 3), and the calibration range was from 1 to 100 pmol with excellent proportionality (R²≥0.9992) for four kinds of PAHQs: benz[a]anthracene-7, 12-dione, fluoranthene-2, 3-dione, pyrene-1, 6-dione, and pyrene-1, 8-dione. PAHQs in SOF of airborne particles collected in Kyoto, Japan were successfully measured using the established analytical method with simple sample-preparation steps: ultrasonic extraction in organic solvent and concentration under reduced pressure and/or a nitrogen stream.en
dc.format.mimetypeapplication/pdf-
dc.language.isojpn-
dc.publisher日本分析化学会ja
dc.publisher.alternativeJapan Society for Analytical Chemistryen
dc.rights© The Japan Society for Analytical Chemistry 2013en
dc.subjectPAH-dioneen
dc.subjectoxygenated PAHsen
dc.subjectPAH-quinoneen
dc.subjectfluorescence detectionen
dc.subjectairborne particulatesen
dc.titleインライン還元-蛍光検出HPLCを用いる多環芳香族炭化水素キノン分析法の改良と大気粒子抽出物への適用ja
dc.title.alternativeImprovement of the Analytical Method for Quinoid Polycyclic Aromatic Hydrocarbons Using HPLC with In-line Reduction and Fluorescence Detection : Application to Soluble Organic Fraction of Airborne Particlesen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.ncidAN00222633-
dc.identifier.jtitle分析化学ja
dc.identifier.volume62-
dc.identifier.issue11-
dc.identifier.spage979-
dc.identifier.epage984-
dc.relation.doi10.2116/bunsekikagaku.62.979-
dc.textversionpublisher-
dc.address京都大学大学院エネルギー科学研究科エネルギー社会・環境科学専攻ja
dc.address金沢大学医薬保健研究域・薬学系ja
dc.address金沢大学医薬保健研究域・薬学系ja
dc.address金沢大学医薬保健研究域・薬学系ja
dc.address金沢大学医薬保健研究域・薬学系ja
dc.address金沢大学医薬保健研究域・薬学系ja
dc.address.alternativeGraduate School of Energy Science, Kyoto Universityen
dc.address.alternativeInstitute of Medical, Pharmaceutical and Health Sciences, Kanazawa Universityen
dc.address.alternativeInstitute of Medical, Pharmaceutical and Health Sciences, Kanazawa Universityen
dc.address.alternativeInstitute of Medical, Pharmaceutical and Health Sciences, Kanazawa Universityen
dc.address.alternativeInstitute of Medical, Pharmaceutical and Health Sciences, Kanazawa Universityen
dc.address.alternativeInstitute of Medical, Pharmaceutical and Health Sciences, Kanazawa Universityen
dc.relation.NAID10031196846-
dcterms.accessRightsopen access-
dc.identifier.jtitle-alternativeJapan analysten
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。