このアイテムのアクセス数: 108

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
2017SBT_FP17.pdf2.25 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorTsutsumi, Daizoen
dc.contributor.authorHigashi, Yutakaen
dc.contributor.authorNonaka, Michinobuen
dc.contributor.authorFujita, Masaharuen
dc.contributor.transcriptionツツミ, ダイゾウ-
dc.contributor.transcriptionヒガシ, ユタカ-
dc.contributor.transcriptionノナカ, ミチノブ-
dc.contributor.transcriptionフジタ, マサハル-
dc.date.accessioned2020-01-29T07:44:20Z-
dc.date.available2020-01-29T07:44:20Z-
dc.date.issued2017-
dc.identifier.urihttp://hdl.handle.net/2433/245501-
dc.description[2nd International Workshop on Sediment Bypass Tunnels = 第2回排砂バイパストンネルに関する国際ワークショップ] May 9-12, Kyoto-Japan, 2017.ja
dc.description特定研究集会: 29C-01ja
dc.description.abstractSurrogate measurements using Swiss geophone plates and Japanese acoustic pipes/plates are effective for monitoring bedload transport in mountainous streams. They are also becoming important tools for obtaining sediment discharge measurements at the outlets of sediment bypass tunnels, to monitor bedload discharge through such tunnels. They have been installed at the bypass tunnel of the Solis dam in Switzerland and the Koshibu dam in Japan. To obtain the practical amount of bedload discharge from surrogate measurements, determining a calibration relationship between geophone impulses/ acoustic pulses and bedload is necessary. We have installed acoustic pipes and a slot sampler in the Ashiarai-dani supercritical flume, located in the Hodaka mountain range, Japan, and have been conducting bedload monitoring for more than a decade. Recently, we developed a new method of analyzing data obtained with a set of horizontal and vertical acoustic pipes, to overcome the disadvantages of bedload measurements obtained using acoustic pipes only: (1) bedload particles saltating over the pipe remain undetected, and (2) saturation problems of acoustic pulses under high-discharge conditions. A vertical pipe was installed on the wall of the flume and the horizontal pipe was installed on the flume bed. We propose a ratio (Rhv) between pulses detected by these sensors, and applied this ratio to calibrate the contemporaneous pulses detected with a pipe located immediately upstream of a bedload slot sampler. Indeed the Rhv-corrected pulses correlated well with the bedload discharge obtained with the slot sampler. We conclude that bedload monitoring using concomitant vertical and horizontal pipes can be used to calibrate a centrally located pipe, thereby representing bedload discharges more accurately than those based on a single acoustic pipe: this monitoring method may be useful at sediment bypass tunnels.en
dc.format.mimetypeapplication/pdf-
dc.language.isoeng-
dc.publisherKyoto Universityen
dc.publisher.alternative京都大学ja
dc.subjectbedload measurementen
dc.subjectsediment bypass tunnelen
dc.subjectacoustic pipesen
dc.subjectvertical pipeen
dc.subjectcalibrationen
dc.titleBedload monitoring in a mountain stream: Method for improving the accuracy of the calibration relationship between acoustic pulses and bedload dischargeen
dc.typeresearch report-
dc.type.niitypeResearch Paper-
dc.identifier.jtitleProceedings of the 2nd International Workshop on Sediment Bypass Tunnels-
dc.identifier.spage1-
dc.identifier.epage10-
dc.textversionauthor-
dc.identifier.artnumFP17-
dc.sortkey21-
dc.addressResearch Center for Fluvial and Costal Disaster, Disaster Prevention Research Institute, Kyoto Universityen
dc.addressGraduate School of Engineering, Kyoto Universityen
dc.addressHydrotech Co. Ltd.en
dc.addressResearch Center for Fluvial and Costal Disaster, Disaster Prevention Research Institute, Kyoto Universityen
dc.relation.urlhttp://hdl.handle.net/2433/235820-
dcterms.accessRightsopen access-
出現コレクション:第2回排砂バイパストンネルに関する国際ワークショップ

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。