このアイテムのアクセス数: 173
このアイテムのファイル:
ファイル | 記述 | サイズ | フォーマット | |
---|---|---|---|---|
s41598-018-38346-0.pdf | 4.54 MB | Adobe PDF | 見る/開く |
タイトル: | Empirical evaluation of variant calling accuracy using ultra-deep whole-genome sequencing data |
著者: | Kishikawa, Toshihiro Momozawa, Yukihide Ozeki, Takeshi Mushiroda, Taisei Inohara, Hidenori Kamatani, Yoichiro Kubo, Michiaki Okada, Yukinori |
著者名の別形: | 岸川, 敏博 桃沢, 幸秀 大関, 健志 莚田, 泰誠 猪原, 秀典 鎌谷, 洋一郎 久保, 充明 岡田, 随象 |
キーワード: | DNA sequencing Immunogenetics Next-generation sequencing |
発行日: | 11-Feb-2019 |
出版者: | Springer Nature |
誌名: | Scientific Reports |
巻: | 9 |
論文番号: | 1784 |
抄録: | In the design of whole-genome sequencing (WGS) studies, sequencing depth is a crucial parameter to define variant calling accuracy and study cost, with no standard recommendations having been established. We empirically evaluated the variant calling accuracy of the WGS pipeline using ultra-deep WGS data (approximately 410×). We randomly sampled sequence reads and constructed a series of simulation WGS datasets with a variety of gradual depths (n = 54; from 0.05× to 410×). Next, we evaluated the genotype concordances of the WGS data with those in the SNP microarray data or the WGS data using all the sequence reads. In addition, we assessed the accuracy of HLA allele genotyping using the WGS data with multiple software tools (PHLAT, HLA-VBseq, HLA-HD, and SNP2HLA). The WGS data with higher depths showed higher concordance rates, and >13.7× depth achieved as high as >99% of concordance. Comparisons with the WGS data using all the sequence reads showed that SNVs achieved >95% of concordance at 17.6× depth, whereas indels showed only 60% concordance. For the accuracy of HLA allele genotyping using the WGS data, 13.7× depth showed sufficient accuracy while performance heterogeneity among the software tools was observed (the highest concordance of 96.9% was observed with HLA-HD). Improvement in HLA genotyping accuracy by further increasing the depths was limited. These results suggest a medium degree of the WGS depth setting (approximately 15×) to achieve both accurate SNV calling and cost-effectiveness, whereas relatively higher depths are required for accurate indel calling. |
著作権等: | © The Author(s) 2019. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
URI: | http://hdl.handle.net/2433/249992 |
DOI(出版社版): | 10.1038/s41598-018-38346-0 |
PubMed ID: | 30741997 |
出現コレクション: | 学術雑誌掲載論文等 |

このリポジトリに保管されているアイテムはすべて著作権により保護されています。