このアイテムのアクセス数: 59
このアイテムのファイル:
ファイル | 記述 | サイズ | フォーマット | |
---|---|---|---|---|
mrms.mp.2021-0065.pdf | 11.84 MB | Adobe PDF | 見る/開く |
完全メタデータレコード
DCフィールド | 値 | 言語 |
---|---|---|
dc.contributor.author | Sakurama, Azusa | en |
dc.contributor.author | Fushimi, Yasutaka | en |
dc.contributor.author | Nakajima, Satoshi | en |
dc.contributor.author | Sakata, Akihiko | en |
dc.contributor.author | Hinoda, Takuya | en |
dc.contributor.author | Oshima, Sonoko | en |
dc.contributor.author | Otani, Sayo | en |
dc.contributor.author | Wicaksono, Krishna Pandu | en |
dc.contributor.author | Liu, Wei | en |
dc.contributor.author | Maki, Takakuni | en |
dc.contributor.author | Okada, Tomohisa | en |
dc.contributor.author | Takahashi, Ryosuke | en |
dc.contributor.author | Nakamoto, Yuji | en |
dc.contributor.alternative | 櫻間, 梓 | ja |
dc.contributor.alternative | 伏見, 育崇 | ja |
dc.contributor.alternative | 中島, 諭 | ja |
dc.contributor.alternative | 坂田, 昭彦 | ja |
dc.contributor.alternative | 日野田, 卓也 | ja |
dc.contributor.alternative | 大嶋, 園子 | ja |
dc.contributor.alternative | 大谷, 紗代 | ja |
dc.contributor.alternative | 眞木, 崇州 | ja |
dc.contributor.alternative | 岡田, 知久 | ja |
dc.contributor.alternative | 髙橋, 良輔 | ja |
dc.contributor.alternative | 中本, 裕士 | ja |
dc.date.accessioned | 2023-01-13T00:21:23Z | - |
dc.date.available | 2023-01-13T00:21:23Z | - |
dc.date.issued | 2022 | - |
dc.identifier.uri | http://hdl.handle.net/2433/278353 | - |
dc.description.abstract | PURPOSE: To compare reliability and elucidate clinical application of magnetization-prepared rapid gradient-echo (MPRAGE) with 9-fold acceleration by using wave-controlled aliasing in parallel imaging (Wave-CAIPI 3 × 3) in comparison to conventional MPRAGE accelerated by using generalized autocalibrating partially parallel acquisition (GRAPPA) 2 × 1. METHODS: A total of 26 healthy volunteers and 33 patients were included in this study. Subjects were scanned with two MPRAGEs, GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 acquired in 5 min 21 s and 1 min 42 s, respectively, on a 3T MR scanner. Healthy volunteers underwent additional two MPRAGEs (CAIPI 3 × 3 and GRAPPA 3 × 3). The image quality of the four MPRAGEs was visually evaluated with a 5-point scale in healthy volunteers, and the SNR of four MPRAGEs was also calculated by measuring the phantom 10 times with each MPRAGE. Based on the results of the visual evaluation, voxel-based morphometry (VBM) analyses, including subfield analysis, were performed only for GRAPPA 2 × 1 and Wave-CAIPI 3 × 3. Correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was assessed. RESULTS: In visual evaluations, scores for MPRAGE GRAPPA 2 × 1 (mean rank: 4.00) were significantly better than those for Wave-CAIPI 3 × 3 (mean rank: 3.00), CAIPI 3 × 3 (mean rank: 1.83), and GRAPPA 3 × 3 (mean rank: 1.17), and scores for Wave-CAIPI 3×3 were significantly better than those for CAIPI 3 × 3 and GRAPPA 3 × 3. Image noise was evident at the center for additional MPRAGE CAIPI 3 × 3 and GRAPPA 3 × 3. The correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was higher than 0.85 in all VOIs except globus pallidus. Subfield analysis of hippocampus also showed a high correlation between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3. CONCLUSION: MPRAGE Wave-CAIPI 3 × 3 shows relatively better contrast, despite of its short scan time of 1 min 42 s. The volumes derived from automated segmentation of MPRAGE Wave-CAIPI are considered to be reliable measures. | en |
dc.language.iso | eng | - |
dc.publisher | Japanese Society for Magnetic Resonance in Medicine | en |
dc.rights | © 2021 by Japanese Society for Magnetic Resonance in Medicine | en |
dc.rights | This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license. | en |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | voxel-based morphometry | en |
dc.subject | magnetization-prepared rapid gradient-echo | en |
dc.subject | wave-controlled aliasing in parallel imaging | en |
dc.subject | generalized autocalibrating partially parallel acquisition | en |
dc.subject | subfield analysis | en |
dc.title | Clinical Application of MPRAGE Wave Controlled Aliasing in Parallel Imaging (Wave-CAIPI): A Comparative Study with MPRAGE GRAPPA | en |
dc.type | journal article | - |
dc.type.niitype | Journal Article | - |
dc.identifier.jtitle | Magnetic Resonance in Medical Sciences | en |
dc.identifier.volume | 21 | - |
dc.identifier.issue | 4 | - |
dc.identifier.spage | 633 | - |
dc.identifier.epage | 647 | - |
dc.relation.doi | 10.2463/mrms.mp.2021-0065 | - |
dc.textversion | publisher | - |
dc.identifier.pmid | 34602534 | - |
dcterms.accessRights | open access | - |
datacite.awardNumber | 18K07711 | - |
datacite.awardNumber | 19K17266 | - |
datacite.awardNumber.uri | https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-18K07711/ | - |
datacite.awardNumber.uri | https://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-19K17266/ | - |
dc.identifier.pissn | 1347-3182 | - |
dc.identifier.eissn | 1880-2206 | - |
jpcoar.funderName | 日本学術振興会 | ja |
jpcoar.funderName | 日本学術振興会 | ja |
jpcoar.awardTitle | 圧縮センシングの脳・頸部MRIへの応用 | ja |
jpcoar.awardTitle | 急性期脳梗塞および脳血管異常のリアルタイム検出 | ja |
出現コレクション: | 学術雑誌掲載論文等 |

このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス