このアイテムのアクセス数: 59

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
mrms.mp.2021-0065.pdf11.84 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorSakurama, Azusaen
dc.contributor.authorFushimi, Yasutakaen
dc.contributor.authorNakajima, Satoshien
dc.contributor.authorSakata, Akihikoen
dc.contributor.authorHinoda, Takuyaen
dc.contributor.authorOshima, Sonokoen
dc.contributor.authorOtani, Sayoen
dc.contributor.authorWicaksono, Krishna Panduen
dc.contributor.authorLiu, Weien
dc.contributor.authorMaki, Takakunien
dc.contributor.authorOkada, Tomohisaen
dc.contributor.authorTakahashi, Ryosukeen
dc.contributor.authorNakamoto, Yujien
dc.contributor.alternative櫻間, 梓ja
dc.contributor.alternative伏見, 育崇ja
dc.contributor.alternative中島, 諭ja
dc.contributor.alternative坂田, 昭彦ja
dc.contributor.alternative日野田, 卓也ja
dc.contributor.alternative大嶋, 園子ja
dc.contributor.alternative大谷, 紗代ja
dc.contributor.alternative眞木, 崇州ja
dc.contributor.alternative岡田, 知久ja
dc.contributor.alternative髙橋, 良輔ja
dc.contributor.alternative中本, 裕士ja
dc.date.accessioned2023-01-13T00:21:23Z-
dc.date.available2023-01-13T00:21:23Z-
dc.date.issued2022-
dc.identifier.urihttp://hdl.handle.net/2433/278353-
dc.description.abstractPURPOSE: To compare reliability and elucidate clinical application of magnetization-prepared rapid gradient-echo (MPRAGE) with 9-fold acceleration by using wave-controlled aliasing in parallel imaging (Wave-CAIPI 3 × 3) in comparison to conventional MPRAGE accelerated by using generalized autocalibrating partially parallel acquisition (GRAPPA) 2 × 1. METHODS: A total of 26 healthy volunteers and 33 patients were included in this study. Subjects were scanned with two MPRAGEs, GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 acquired in 5 min 21 s and 1 min 42 s, respectively, on a 3T MR scanner. Healthy volunteers underwent additional two MPRAGEs (CAIPI 3 × 3 and GRAPPA 3 × 3). The image quality of the four MPRAGEs was visually evaluated with a 5-point scale in healthy volunteers, and the SNR of four MPRAGEs was also calculated by measuring the phantom 10 times with each MPRAGE. Based on the results of the visual evaluation, voxel-based morphometry (VBM) analyses, including subfield analysis, were performed only for GRAPPA 2 × 1 and Wave-CAIPI 3 × 3. Correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was assessed. RESULTS: In visual evaluations, scores for MPRAGE GRAPPA 2 × 1 (mean rank: 4.00) were significantly better than those for Wave-CAIPI 3 × 3 (mean rank: 3.00), CAIPI 3 × 3 (mean rank: 1.83), and GRAPPA 3 × 3 (mean rank: 1.17), and scores for Wave-CAIPI 3×3 were significantly better than those for CAIPI 3 × 3 and GRAPPA 3 × 3. Image noise was evident at the center for additional MPRAGE CAIPI 3 × 3 and GRAPPA 3 × 3. The correlation of segmentation results between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3 was higher than 0.85 in all VOIs except globus pallidus. Subfield analysis of hippocampus also showed a high correlation between GRAPPA 2 × 1 and Wave-CAIPI 3 × 3. CONCLUSION: MPRAGE Wave-CAIPI 3 × 3 shows relatively better contrast, despite of its short scan time of 1 min 42 s. The volumes derived from automated segmentation of MPRAGE Wave-CAIPI are considered to be reliable measures.en
dc.language.isoeng-
dc.publisherJapanese Society for Magnetic Resonance in Medicineen
dc.rights© 2021 by Japanese Society for Magnetic Resonance in Medicineen
dc.rightsThis article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.en
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectvoxel-based morphometryen
dc.subjectmagnetization-prepared rapid gradient-echoen
dc.subjectwave-controlled aliasing in parallel imagingen
dc.subjectgeneralized autocalibrating partially parallel acquisitionen
dc.subjectsubfield analysisen
dc.titleClinical Application of MPRAGE Wave Controlled Aliasing in Parallel Imaging (Wave-CAIPI): A Comparative Study with MPRAGE GRAPPAen
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleMagnetic Resonance in Medical Sciencesen
dc.identifier.volume21-
dc.identifier.issue4-
dc.identifier.spage633-
dc.identifier.epage647-
dc.relation.doi10.2463/mrms.mp.2021-0065-
dc.textversionpublisher-
dc.identifier.pmid34602534-
dcterms.accessRightsopen access-
datacite.awardNumber18K07711-
datacite.awardNumber19K17266-
datacite.awardNumber.urihttps://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-18K07711/-
datacite.awardNumber.urihttps://kaken.nii.ac.jp/grant/KAKENHI-PROJECT-19K17266/-
dc.identifier.pissn1347-3182-
dc.identifier.eissn1880-2206-
jpcoar.funderName日本学術振興会ja
jpcoar.funderName日本学術振興会ja
jpcoar.awardTitle圧縮センシングの脳・頸部MRIへの応用ja
jpcoar.awardTitle急性期脳梗塞および脳血管異常のリアルタイム検出ja
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このアイテムは次のライセンスが設定されています: クリエイティブ・コモンズ・ライセンス Creative Commons