このアイテムのアクセス数: 16

このアイテムのファイル:
ファイル 記述 サイズフォーマット 
edn3.44.pdf1.12 MBAdobe PDF見る/開く
完全メタデータレコード
DCフィールド言語
dc.contributor.authorTsuji, Satsukien
dc.contributor.authorMiya, Masakien
dc.contributor.authorUshio, Masayukien
dc.contributor.authorSato, Hirotoshien
dc.contributor.authorMinamoto, Toshifumien
dc.contributor.authorYamanaka, Hirokien
dc.contributor.alternative潮, 雅之ja
dc.contributor.alternative佐藤, 博俊ja
dc.date.accessioned2025-04-15T07:50:23Z-
dc.date.available2025-04-15T07:50:23Z-
dc.date.issued2020-01-
dc.identifier.urihttp://hdl.handle.net/2433/293321-
dc.description.abstractRecent advances in environmental DNA (eDNA) analysis using high-throughput sequencing (HTS) provide a noninvasive way to evaluate the intraspecific genetic diversity of aquatic macroorganisms. However, erroneous sequences present in HTS data can result in false positive haplotypes; therefore, reliable strategies are necessary to eliminate such erroneous sequences when evaluating intraspecific genetic diversity using eDNA metabarcoding. In this study, we propose an approach combining denoising using amplicon sequence variant (ASV) method and the removal of haplotypes with low detection rates. A mixture of rearing water of Ayu (𝘗𝘭𝘦𝘤𝘰𝘨𝘭𝘰𝘴𝘴𝘶𝘴 𝘢𝘭𝘵𝘪𝘷𝘦𝘭𝘪𝘴 𝘢𝘭𝘵𝘪𝘷𝘦𝘭𝘪𝘴) was used as an eDNA sample. In total, nine haplotypes of Ayu mitochondrial D-loop region were contained in the sample and amplified by two-step tailed PCR. The 15 PCR replicates indexed with different tags were prepared from the eDNA sample to compare the detection rates between true haplotypes and false positive haplotypes. All PCR replications were sequenced by HTS, and the total number of detected true haplotypes and false positive haplotypes was compared with and without denoising using the two types of ASV methods, Divisive Amplicon Denoising Algorithm 2 (DADA2) and UNOISE3. The use of both ASV methods considerably reduced the number of false positive haplotypes. Moreover, all true haplotypes were detected in all 15 PCR replicates, whereas false positive haplotypes had detection rates varying from 1/15 to 15/15. Thus, by removing haplotypes with lower detection rates than 15/15, the number of false positive haplotypes was further reduced. The approach proposed in this study successfully eliminated most of the false positive haplotypes in the HTS data obtained from eDNA samples, which allowed us to improve the detection accuracy for evaluating intraspecific genetic diversity using eDNA analysis.en
dc.language.isoeng-
dc.publisherWileyen
dc.subjectASV methodsen
dc.subjectenvironmental DNAen
dc.subjecterroneous sequencesen
dc.subjectintraspecific genetic diversityen
dc.subjectmitochondrial haplotypeen
dc.titleEvaluating intraspecific genetic diversity using environmental DNA and denoising approach: A case study using tank wateren
dc.typejournal article-
dc.type.niitypeJournal Article-
dc.identifier.jtitleEnvironmental DNAen
dc.identifier.volume2-
dc.identifier.issue1-
dc.identifier.spage42-
dc.identifier.epage52-
dc.relation.doi10.1002/edn3.44-
dc.textversionpublisher-
dcterms.accessRightsopen access-
dc.identifier.pissn2637-4943-
出現コレクション:学術雑誌掲載論文等

アイテムの簡略レコードを表示する

Export to RefWorks


出力フォーマット 


このリポジトリに保管されているアイテムはすべて著作権により保護されています。